TYPE |
YZ101B |
Accuracy class according to OIML R60 |
|
- |
C3 |
Maximal numbers of load cell verification intervals (nlc) |
|
3000 |
3000 |
Maximal capacity (Emax) |
kg |
50;100;200 |
300;500;
1000;2000 |
Weight (G),approx. |
kg |
0.65 |
0.8 |
Minimumload cell verification interval (Vmin) |
% of Cn |
0.03 |
Sensitivity (Cn) |
mV/V |
2 ± 0.25% |
Zero balance |
mV/V |
0 ± 2% |
Temperature effect on sensitivity (TKc)* |
% of Cn/k |
< ± 0.0012 |
Temperature effect on zero balance (TKo) |
% of Cn/k |
< ± 0.0040 |
Non-linearity (dlin)* |
% |
< ± 0.017 |
Repeatability (drep)* |
% |
< ± 0.017 |
Hysteresis error (dhy)* |
% |
< ± 0.017 |
Creep (dDR) in 30 min |
% |
< ± 0.023 |
Input resistance (RLC) [Red(+)-white(-)] |
W |
400 ± 25 |
Output resistance (Ro) [blue(+)-green(-)] |
W |
350 ± 3 |
Reference excitation voltage (Uref) |
V (DC/AC) |
0.5 ... 12 |
Maximal excitation voltage |
V (DC/AC) |
18 |
Insulation resistance (Ris) |
G |
< 2 [50 VCD] |
Nominal temperature rang |
˚C [˚F] |
-10…+40[15…+105] |
Service temperature range |
˚C [˚F] |
-25...+70[15…+160] |
Storage temperature range |
˚C [˚F] |
-50…+85[-60…-+185] |
Safe load limit (EL) |
% of Cn |
150 |
Breaking load (Ed) |
% of Cn |
300 |
Protection class (IP) acc. to IEC529 |
|
IP66 |
Material |
|
Steel alloy |
Optionally |
|
Explosion proof version
(Ex ib II CT4) |